| Features | Benefits |
|---|---|
| Supports up to 8 Primary Door Interface (PDI) boards per board | Control of up to 8 doors with Keypads and Readers. |
| Supports up to 8 Supervised Lines, 32 with 8 PDIs installed | Complete monitoring of Alarms and Tampers at all doors. |
| Supports the Ademco polling loop RPM 4208 modules. | Up to 16 additional medium line supervision inputs. |
|
Number of Fully Supervised
Lines Type of Line Supervision Typical Supervision Currents |
8, 40 with 8 PDI's Multilevel 100uA |
|
Card Readers supported Input Standard LEDs per card reader |
4 or 8 Wiegand or ABA (Clock and Data) 2 |
|
Keypads supported Configuration PIN Digits LEDs per keypad |
1 per RS-485 card reader
or P/SDI 3x4 or 4x4 Configurable 1 |
|
Digital Inputs Isolated Outputs Configuration Current @ 5 to 60 VDC, 45 degrees C Current @ 24 to 140 VAC, 45 degrees C Fuse |
8, 24 with P/SDI (may
also be used as request to exit) 8, 24 with PDI Industry standard output modules AC N.O. (1 Form A) or N.C. (1 Form B) DC N.O or low current dry contact N.O. 3 Amps continuous, 5 Amps 1 second surge 3 Amps continuous, 80 Amps single cycle surge Per output, 5Amps |
|
Processor Clock Speed Logic Type |
12MHz CMOS |
| Ademco Polling Loop Module Compatibility | Ademco RPM 4208 |
|
Communication to PDI/SDI Boards Communications Baud Rate Error Detection |
8 RS-485 Half (2 wire) or full (4 wire) duplex 19.2K Baud (RS-485) CRC-CCITT |
|
Terminal
Interface Signaling Standard Baud Rates |
1 RS-232D 19,200 |
|
Power Required Temperature Range Dimensions |
10 to 13 VDC, 100 to 400mA. 80%
efficient -5 to 65 degrees C, Operating 4" by 11" |