Number of Supervised Lines Type of Line Supervision Typical Supervision Currents |
4 Multilevel 100uA |
|
Card Readers supported Input Standard LEDs per card reader Beeper per card reader |
1 Wiegand or ABA (Clock and Data) 2 1 |
|
Keypads supported Configuration PIN Digits LEDs per keypad |
1 3x4 or 4x4 Configurable 1 |
|
Digital Inputs Isolated Outputs Configuration Current @ 24 VDC, 45 degrees C Fuse |
3 (tamper, access, request
to exit) 2 Industrial output modules DC N.O or low current dry contact N.O. 3 Amps continuous, 5 Amps 1 second surge Per output, 5 Amps |
|
Terminations Terminal Spacing Largest Wire Size |
Compression 0.225" 14AWG |
|
Host Communication Protocol Baud Rate Error Detection |
RS-485, 2 wire Lantek 9 Bit 19.2K Baud CRC-CCITT |
|
Power Required Temperature Range Dimensions |
12 to 14 VDC, 100 to 400mA. 80%
efficient -5 to 65 degrees C, Operating 3" by 6" |